Sensor

Sensor Table

The Sensor Table includes all of the information related to the sensors used in the testing. It includes the names, types and location of the sensors. 

 

The Calibration Factors were used during data processing to convert voltages acquired into engineering units for each type of sensor. They are included in the database for completeness. 

 

 For more information about the CC8 Phase 1 Overload sensors, click here. 

 

TestItemName Name associated with the test section item number

SensorID

Number used for sensor identification

SensorName

Name assigned to the sensor. The first letters identify the sensor type

SensorType

Information such as full bridge, vertical displacement, and deflection

Unit

Units the sensors record in

GageType

Returns thermocouple, moisture sensors, embedded gage, potentiometer, and eddy current sensors

LocationX_FT

Sensor location X coordinate in feet from Instrumentation Plan

LocationY_FT

Sensor location Y coordinate in feet from Instrumentation Plan

LocationZ_FT

Sensor location Z coordinate in feet from Instrumentation Plan

Depth_IN Sensor location form surface in inches
Calibration Factor 1 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 2 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 3 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 4 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 5 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
Calibration Factor 6 Parameters used during data processing, includes sensor position as well as sensor scaling and offset values
SPUNo Number of the Signal Processing Unit (SPU) used to acquire dynamic data from SenosrName
Card Pertains to physical DAQ connection

Channel

Pertains to physical DAQ connection

Channel Status

Pertains to physical DAQ connection – 1 is collect, 0 is no collection

Mux

Number assigned to the multiplexer (MUX) used to acquire static data from SensorName

PhaseID

CC8 Phase ID

 

Return to Search CC8 Phase 1 Database 

 


 

Query Sensor Data

TestItemNameSensorIDSensorNameSensorTypeUnitGageTypeLocationX_FTLocationY_FTLocationZ_FTDepth_INCalibrationFactor1CalibrationFactor2CalibrationFactor3CalibrationFactor4CalibrationFactor5CalibrationFactor6SPUNoCardChannelChannelStatusPhaseIDMUXComments
1N83102EG-N-O-I-3Full Bridge microstrainEmbedded Gage342.25-11.0057.0811.00728.75561342.25-111131211  
1N83103EG-N-O-I-4Full Bridge microstrainEmbedded Gage342.25-11.0056.5018.00745561342.25-111831311  
1S83122EG-S-O-I-3Full Bridge microstrainEmbedded Gage342.2511.0057.0811.00703.75571342.251111311011  
1S83123EG-S-O-I-4Full Bridge microstrainEmbedded Gage342.2511.0056.5018.00763.5571342.251118311111  
2N83106EG-N-O-I-7Full Bridge microstrainEmbedded Gage346.00-14.7557.0811.00675561346-14.751131611  
2N83107EG-N-O-I-8Full Bridge microstrainEmbedded Gage346.00-14.7556.5018.00736.25561346-14.751831711  
2S83126EG-S-O-I-7Full Bridge microstrainEmbedded Gage346.0014.7557.0811.00730.557134614.7511311411  
2S83127EG-S-O-I-8Full Bridge microstrainEmbedded Gage346.0014.7556.5018.00753.557134614.7518311511  
3N83117POT-N-O-I-2Vertical Displacement milsPotentiometer354.25-14.7556.4219.001000584.623354.25-14.7519311711 Sensor not responding
3S83137POT-S-O-I-2Vertical Displacement milsPotentiometer354.2514.7556.4219.001000583.223354.2514.7519312111  
1 2 3 4 5 6